QUESTION 51
An administrator has configured an alarm to be notified when a virtual machine meets either of these conditions:
High virtual CPU
High active memory consumption.
The alarm is only triggering when both of the conditions are met.
What can be done to correct the alarm behavior?

A.    Edit the alarm and select Trigger if ANY of the following conditions are satisfied.
B.    Edit the alarm and select Trigger if ALL of the following conditions are satisfied.
C.    Create two separate alarms, one for CPU and one for memory and link them together with ESXCLI.
D.    Delete the existing alarm and create a new event based alarm.

Answer: A

QUESTION 52
What may be a cause for failure to unmount an NFS datastore?

A.    It has active snapshot files.
B.    It is being used for High Availability (HA) heartbeat.
C.    It is part of a Cluster.
D.    It is managed by Distributed Resource Scheduler (DRS).

Answer: A

QUESTION 53
Which two statements are true about deploying and using vSphere Replication? (Choose two.)

A.    ESXi hosts managed by a single vCenter Server instance require a connection between the two vSphere Replication appliances.
B.    Sites managed by different vCenter Server instances require a connection between the two vSphere Replication appliances.
C.    Sites managed by different vCenter Server instances require the use of Site Recovery Manager and a connection between the two vSphere Replication appliances.
D.    ESXi hosts managed by a single vCenter Server instance require a single vSphere Replication appliance.

Answer: BD

QUESTION 54
An attempt to enable vSphere Fault Tolerance for a powered-on virtual machine fails.
Which two scenarios would result in this failure? (Choose two.)

A.    The virtual machine has three vCPUs configured.
B.    The host on which the virtual machine is running has insufficient memory resources.
C.    The virtual machine has insufficient resources to accommodate full reservation plus the overhead memory.
D.    VMware High Availability is enabled on the cluster of which this host is a member.

Answer: BC

QUESTION 55
A Fault Tolerance (FT) virtual machine with four vCPUs is experiencing high latency when performing ICMP and Application tests.
What are three potential causes that may be attributing to this latency? (Choose three.)

A.    The FT network has insufficient bandwidth and is running on a 1GB Link.
B.    The FT network is on a particularly high latency link.
C.    The FT network has been configured with Network I/O Control.
D.    The FT virtual machine is running an e1000 network adapter.
E.    The FT virtual machine is running on poor performing network-based storage.

Answer: ABC

QUESTION 56
VMware tools is failing to install on a Microsoft Windows virtual machine.
What are two possible situations that would prevent the installation? (Choose two.)

A.    The VMware tools installation media is corrupt.
B.    The incorrect Operating System was selected in the virtual machine options.
C.    The software prerequisites have not been installed.
D.    The prerequisite services have not been started.

Answer: AB

QUESTION 57
What is true regarding datastores on ESXi 6.x?

A.    NFS 4.1 datastore does not support Fault Tolerance (FT)
B.    VMFS3 and VMFS5 datastores can be newly created
C.    NFS datastore can be concurrently mounted using NFS 4.1 on one host and NFS on another
D.    NFS 3.0 datastore does not support Fault Tolerance (FT)

Answer: A

QUESTION 58
An administrator is performing a scripted installation of ESXi 6.x.
In which three locations does the script need to be? (Choose three.)

A.    PXE Server
B.    HTTPS
C.    FTP
D.    NFS
E.    VVOLs Datastore

Answer: BCD

QUESTION 59
Which three features are not supported when using Fault Tolerance in vSphere 6.x? (Choose three.)

A.    Virtual Volumes (VVOLS)
B.    Storage vMotion
C.    Virtual Machine Component Protection
D.    vMotion
E.    vSphere Distributed Switches

Answer: ABC

QUESTION 60
Refer to the Exhibit. An administrator is configuring an ESXi 6.x host to use multiple NICs to resolve a management network redundancy error. After configuring a second NIC, the server is not able to communicate when the primary connection is taken down.
The administrator analyzes the Exhibit shown here.
 
Based on the exhibit, what is the likely cause of the issue?

A.    vmnic4 is not attached to a vSwitch.
B.    vmnic2 is not connected to a physical switch.
C.    E1000 is the incorrect NIC Driver for this card.
D.    There is a MAC address conflict on the network.

Answer: B